Terso Secure
5 min
about rfid enclosures are cabinet, freezer and refrigerator jetstream devices they not only support most jetstream commands and events but extend them by enabling access control and the ability to remotely lockdown to learn more about the specific terso devices that match this device type, visit their product detail pages at tersosolutions com terso cabinets https //www tersosolutions com/rfid cabinets terso freezers https //www tersosolutions com/rfid freezers terso refrigerators https //www tersosolutions com/rfid refrigerators commands you can send the following commands to an rfid enclosure via jetstream name secure enclosure rfid enclosure get device status docid 0r9xzn3hnqid911qs3wxg ✓ ✓ sync device credentials docid\ l7ik ra1wcy3phhm0fwqs ✓ ✓ get all rfid tags docid 7onvtntdtfl9ptdal2nvo − ✓ restart a device docid\ ww54y7kiqnfvyk8zyqakv ✓ ✓ lockdown a device docid\ vboyeohcjlpy 7zr afgz ✓ ✓ unlock a device's door docid 1 ro5cpawezhguxfhofai ✓ ✓ get last device credentials sync date/time docid\ xcfht1rs4l0m0ssfmpz8e ✓ ✓ events the following are the jetstream events that may come into your queue directly from an rfid enclosure other events pertaining to, but not generated by, the rfid enclosure are not listed here as those jetstream generated events do not vary by device type see the event entry in the glossary docid\ k wnsotemg6 ggtqd 6gs to see a complete list of which events are from a device and which come from the jetstream application name supported notes secure enclosure rfid enclosure aggregateevent docid\ atqjfemfm4z9hitjaiepk yes an aggregateevent is generated whenever an rifd tag has been added or removed from a device − ✓ commandcompletionevent docid\ sj1tshbqvf4fri6az1ywg yes a commandcompletionevent is published when a command has been completed on a device ✓ ✓ heartbeatevent docid\ g o0yv1ty07c7b ce rdw yes these can be disabled by setting the heartbeateventinterval config parameter to 0 ✓ ✓ logentryevent docid\ cclcl11t3bliaiko gtmh yes these can be disabled or increased by configuring the logentrylevel config parameter disabling logentryevents is not recommended, as this would prevent you or terso from remotely monitoring the health of the unit see the logentryevents section below for more details ✓ ✓ objectevent docid 6kkkdbv1sxgpehyq9dh0j yes these can be disabled by setting the objecteventhour config parameter to 1 − ✓ sensorreadingevent docid\ rgpeiorzuhkz9iqamwxmp yes see the sensorreadingevents section below for more details − ✓ statusevent docid\ wfpf7d 2jsp7uavkaqvmp yes a statusevent reports several pieces of device information every time the device is powered on, and during its nightly scan ✓ ✓ logentryevents the list below are some common, potential logentryevents docid\ cclcl11t3bliaiko gtmh an rfid enclosure may send in however, not all possible logentryevents are listed in this table the logentrylevel config parameter determines which logentryevents are sent to jetstream, the following logentryevents may be sent when logentrylevel = error name description secure enclosure rfid enclosure acpowerfailure acpowerfailure occurs when the enclosure loses ac power and is running on battery backup ✓ ✓ acpowerrestore acpowerrestore occurs when the enclosure has ac power restored ✓ ✓ corruptflash corruptflash occurs when the enclosure believes there is a problem with the flash memory − ✓ doorbreach doorbreach occurs when the door lock is released by something other than the enclosure for example, someone prying the door open would cause this logentryevent to be generated ✓ ✓ dooropen dooropen occurs when the door is left open for greater than the dooropentimelimit ✓ ✓ dooropenrestore dooropenrestore occurs when the enclosure's door is closed after a dooropen scenario ✓ ✓ doorsensorfailure doorsensorfailure occurs when the enclosure believes there is a problem with the door sensor ✓ ✓ displayfailure displayfailure occurs when the firmware attempts to send a message to the lcd but fails − ✓ displayrestore displayrestore occurs when communication with the lcd is restored − ✓ invalidpass invalidpass occurs when an rfid pass is presented to the pass reader which does not match any value on the enclosure’s synced credentials list ✓ ✓ lowbattery lowbattery occurs when the enclosure's internal ups battery voltage is less than the batterythreshold ✓ ✓ lowflashmemory lowflashmemory occurs when the enclosure has less than 25% flash memory ✓ ✓ lowmemory lowmemory occurs when the enclosure has less than 25% memory this event will be sent every hour until the device reboots reboot occurs automatically if memory drops to 10% ✓ ✓ newfirmwaredownloaderror newfirmwaredownloaderror occurs when a request to upgrade firmware fails ✓ ✓ readexception readexception occurs when there is an issue performing an rfid scan − ✓ scaninterruptionalarm scaninterruptionalarm occurs when someone interrupts a scan by opening the door − ✓ shutdown shutdown occurs when the enclosure is powered down ✓ ✓ startup startup occurs whenever the enclosure is started up ✓ ✓ temperature temperature occurs when a temperature threshold set by sensora/blogentryeventhightemp or sensora/blogentryeventlowtemp has been reached − ✓ temperaturerestore temperaturerestore occurs when an enclosure has gone back into normal temperature range − ✓ userpassreaderfailure userpassreaderfailure occurs when the enclosure loses its connection to the pass reader ✓ ✓ userpassreaderrestore userpassreaderrestore occurs when the enclosure has restored a connection to the pass reader ✓ ✓ validpass validpass occurs when a valid pass is read by the pass reader ✓ ✓ sensorreadingevents enclosures typically have two temperature probes installed, smaller units may only have one probe (a) a sensorreadingevent docid\ rgpeiorzuhkz9iqamwxmp is periodically generated reporting the temperature on the probe(s) name description secure enclosure rfid enclosure temperaturea the temperature reported on probe a in celsius − ✓ temperatureb the temperature reported on probe b in celsius − ✓